Characteristics for connection:

Supply voltage: 24 VDC

Data of standard LEDs

Colour

Forward Current IF [mA]

Forward Voltage UF [V]

red

40

2,0 (IF = 10 mA)

green

40

2,0 (IF = 10 mA)

yellow

40

2,0 (IF = 10 mA)

blue

20

3,2 (IF = 10 mA)

red/green (piezo switches)

20

2,0 (IF = 10 mA)

red/green (switches with stroke)

25

2,0 / 2,2 (IF = 20 mA)

2. Ring illumination

This design is homogeneous and available in red, green, yellow, blue and bi-coloured red/green as standard colours. Ring illuminations in other colours are also possible.

Data of standard LEDs

Colour

Current IF [mA]

red

20

green

20

yellow

20

blue

20

Characteristics for connection:

Supply voltage: 24 VDC

Functional Description Piezo Switches Illumination

Ring Illumination

Single or bi-colored ring illumination is possible for the PSE switches.

When equipped with two colors, it is possible to either switch between the colors or to achieve a combination color, depending on the type of activation.

For example: Diodes of group 1 = red and diodes of group 2 = green

Only group 1 is activated → Ring has red illumination

Only group 2 is activated → Ring has green illumination

Both groups are activated at the same time → Ring has orange illumination

Red cable = Supply voltage: red LEDs

Green cable = Supply voltage: green LEDs

Black cable = Minus for all LEDs

White cable = Switch contact

 Terminal layout:

 Ring Illumination for M24, M27, M30 series - 12 / 24 VDC

Ring Illumination for M22 series - 12 / 24 VDC with Wires

Ring Illumination for M22 series - 12 / 24 VDC with Plug Connector

Ring Illumination Special Type 5 VDC - on request

Point Illumination

 When illuminating the PSE switch, either a single-color LED (2 pins) is used or a bi-colored LED (3 pins). If a single-color LED is used, cable No. 2 is not needed (see terminal layout).

Switching between colors can be achieved by appropriate activation.

Terminal layout:

Point Illumination

ScrollToTop
CloseYou will be transferred to the selected country page address. Therefore you will leave the SCHURTER main page.
If you would you like to visit your selected country page, please click on the button below:
If you would like to stay on the SCHURTER global website, please click on the button below:www.schurter.com
Note: Your country preferences for the SCHURTER Global Website are now saved.