TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  1-pole Rocker red Flange black
1-pole
Rocker red
Flange black
TA36 Rocker  1-pole Rocker green Flange white
1-pole
Rocker green
Flange white
TA36 Rocker  2-pole Rocker black Flange black
2-pole
Rocker black
Flange black
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole
TA36 Rocker  1-pole Rocker red Flange black
TA36 Rocker  1-pole Rocker green Flange white
TA36 Rocker  2-pole Rocker black Flange black

Series: TA36 Rocker

Circuit Breaker for Equipment thermal, Rocker actuation, 1-/2-pole

New_Logo Free Sample Request

31 Variants


Description

  • Thermal circuit breaker
  • 1-/2 pole
  • Snap-in version
  • Positively trip-free release
  • Method of operation acc. to IEC: S-type
  • Different rocker and flange colours
  • Wide current range

Unique Selling Proposition

  • Unique UL rating of 277 VAC
  • Finely graded rated currents
  • High configurability (rocker colours, lettering)
  • Appealing design

Applications

  • Power tools
  • Medical and laboratory equipment
  • Industrial appliances
  • Equipment for construction
  • Cleaning equipment
  • Commercial and household kitchen appliances
  • Industrial Power
  • Industrial lighting arrays

Rated Voltage AC

IEC: 240 VAC

UL/CSA : 277 VAC

Rated Voltage DC

1-pole: 32 VDC / 2-pole: 60 VDC

Rated current range AC

0.05 - 20 A

Conditional short circuit capacity Inc

IEC 60934: 0.05...20 A: 2 kA, SC (C1) @ 240 VAC 

Degree of Protection

front side IP40 acc. to IEC 60529

Dielectric Strength

50 Hz: > 2.5 kV
Impulse 1.2/50 μs: > 4 kV

Insulation Resistance

500 VDC > 100 MΩ

Lifetime

mechanical: 1-/2-pole: 50'000 switching cycles

AC: 1 x Ir, cos φ 0.6:
1-pole: 30'000 / 2-pole: 50'000 switching cycles

DC: 1 x Ir, L/R = 2 - 3 ms:
1-/2-pole: 50'000 switching cycles

Overload

(AC) IEC: min. 40 trips
@ 6 x Ir, cos φ 0.6

(AC) UL / CSA: min. 50 trips
@ 1.5 x Ir, cos φ 0.75

(DC) IEC : min. 40 trips 
 @ 4 x Ir , (L/R=2..3ms)

(DC) UL / CSA : min. 50 trips 
 @ 1.5 x Ir , (t.c.=non.ind.)

Allowable Operation Temp.

-30 °C to 60 °C

Storage Temperature

-40 °C to 60 °C

Vibration Resistance

± 0.75 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Tc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Tc

Shock Resistance

30 G / 18 ms
acc. to IEC 60068-2-27, test Ea

Tripping Type

Thermal 

Actuation Type

Rocker 

Weight

1-pole 19 g - 2-pole 32 g

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: TA36

Approval Logo Certificates Certification Body Description
Approval marks VDE VDE VDE Certificate Number: 40019754
Approval marks cURus UL UR File Number: E71572


Product standards

Product standards that are referenced

Organization Design Standard Description
Partners IEC_Certification_Body Designed according to IEC 60934 Circuit-breakers for equipment (CBE)
Partners UL_Certification_Body Designed according to UL 1077 Standard for Supplementary Protectors for Use in Electrical Equipment
Partners CSA_Certification_Body Designed according to CSA C22.2 No. 235 Supplementary Protectors


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Suitable for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Approval marks Zulassung_Symbol_UKCA SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_50_non_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.

040193000000008860
LOADING...

Dimension [mm]

1-pole

Panel cut-out

Panel cut-out

2 Pole
2-pole


Diagrams

1-pole, 1 bimetal, non illuminated

1) Line, 2) Load
Codepos AAA = CFT, CGT
2-pole, 1 bimetal, non illuminated

1) Line, 2) Load
2-pole, 2 bimetal, non illuminated

1) Line, 2) Load

Approval Rated current Rated Voltage AC Rated Voltage DC
curus UL 1077 0.05...20 A 277 V 32/60 V
curus CSA C22.2 235 0.05...20 A 277 V 32/60 V
VDE IEC 60934 0.05...20 A 240 V 32/60 V

Typical internal resistance per pole

Rated Current [A] Internal Resistance [Ω]
0.05 200.0000
0.1 70.0000
0.2 18.8000
0.3 8.6500
0.4 4.4000
0.5 2.7500
0.8 0.9100
1.0 0.7200
1.2 0.5000
1.5 0.3400
2.0 0.1870
2.5 0.1150
3.0 0.0590
3.5 0.0590
4.0 0.0590
5.0 0.0440
6.0 0.0280
7.0 0.0142
8.0 0.0142
10.0 0.0109
12.0 0.0086
13.0 0.0072
14.0 0.0072
15.0 0.0056
16.0 0.0056
18.0 0.0052
20.0 0.0052

Time-Current-Curves

Tripping Characteristics In < 3 A

Time in Seconds
Multiple of Rated Current In


Ambient temperature +23°
Tripping Characteristics In 3 -20 A

Time in Seconds
Multiple of Rated Current In


Ambient temperature +23°

Effect of ambient temperature

Ambient Temperature [°C] Correction factor  
  1-pole 2-pole
-30 0.77 0.76
-20 0.81 0.81
0 0.90 0.90
+23 1.00 1.00
+40 1.03 1.03
+50 1.04 1.04
+60 1.06 1.06


Short Table of Variants TA36 Rocker Open complete table TA36 Rocker

Basic function Rocker Marking Order Number

Variant Details


The link on the respective order number refers to a separat tab with specific detailed information .
This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.
This approach offers to use generic alias link to the product details:
www.schurter.xx/art/ [Order Number]
where the following variables are used:
- xx is the country specific domain
- [Order Number]

A=Most Popular

A=Most Popular


Most popular products have the following customer benefits:
- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle
Contact us for availability on other product variants, lead-times vary:
Contact-Form Availability for all products can be searched real-time. Enter part number and required quantity:
Stock Check SCHURTER

Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links refers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.
The stock availability at the distributors may also be called up separately and the desired product manually entered.
Stock Check Distributor

...
 
1 pole, 1 bimetal white I/O; embossed 3-125-263 ...
1 pole, 1 bimetal white I/O; embossed 3-128-204 ...
1 pole, 1 bimetal green I/O; embossed 3-128-208 ...
1 pole, 1 bimetal black ON/OFF; white 3-128-211 ...
1 pole, 1 bimetal black I/O; white 3-128-212 ...
1 pole, 1 bimetal black I/O; embossed 3-128-197 ...
1 pole, 1 bimetal yellow I/O; black 3-128-198 ...
1 pole, 1 bimetal black I/O; embossed 3-128-199 ...
1 pole, 1 bimetal green ON/OFF; white 3-128-213 ...
1 pole, 1 bimetal red I/O; black 3-128-200 ...
1 pole, 1 bimetal white I/O; embossed 3-128-201 ...
2 pole, 2 bimetal black I/O; white 3-128-214 ...
2 pole, 2 bimetal black I/O; white 3-128-215 ...
2 pole, 2 bimetal green I/O; embossed 3-128-216 ...
2 pole, 2 bimetal white I/O; black 3-128-240 ...
2 pole, 2 bimetal black ON/OFF; white 3-128-230 ...
2 pole, 2 bimetal black I/O; white 3-128-231 ...
2 pole, 2 bimetal white I/O; embossed 3-128-217 ...
2 pole, 2 bimetal white I/O; black 3-128-218 ...
2 pole, 2 bimetal black I/O; white 3-128-327 ...
2 pole, 2 bimetal black I/O; embossed 3-128-232 ...
2 pole, 2 bimetal white I/O; embossed 3-128-233 ...
2 pole, 2 bimetal green I/O; white 3-128-234 ...
2 pole, 2 bimetal black I/O; white 3-128-235 ...
2 pole, 2 bimetal white I/O; black 3-128-219 ...
2 pole, 2 bimetal white I/O; embossed 3-128-236 ...
2 pole, 2 bimetal white I/O; embossed 3-128-221 ...
2 pole, 2 bimetal green I/O; embossed 3-128-238 ...
2 pole, 2 bimetal black I/O; embossed 3-128-239 ...
2 pole, 2 bimetal black I/O; white 3-128-243 ...
2 pole, 2 bimetal white I/O; black 3-128-244 ...

Packaging Unit
1-pole 20 pcs.
2-pole 10 pcs.

040193000000008860