Free Sample
Please ask for free sample in order to check if the products meets your requirement for your application.
Send your delivery adress and your specific requirements.
Rated Voltage AC
AC 240 VAC
Rated Voltage DC
48 VDC
Rated current range AC
0.05 - 16 A
Conditional short circuit capacity Inc
IEC 60934: PC1, AC 240 V: 2 kA
Short circuit capacity Icn
IEC 60934: at In < 6.5 A/240 VAC : 8 x In
IEC 60934: at In ≥ 6.5 A/240 VAC : 96 A
Degree of Protection
front side IP40 acc. to IEC 60529
Dielectric Strength
50 Hz: > 1.5 kV
Impulse 1.2/50 μs: > 2.5 kV
Insulation Resistance
500 VDC > 100 MΩ
Endurance typical
2 x Ir: 500 switching cycles
Endurance minimum
Reset type
AC : 2 x Ir , cos φ 0.6 :
DC : 2 x Ir , L/R = 2 - 3 ms :
50 switching cycles
Overload
IEC: min. 40 trips
@ 6 x Ir, cos φ 0.6
UL / CSA: min. 50 trips
@ 1.5 x Ir, cos φ 0.75
Allowable Operation Temp.
-5 °C to 60 °C
Vibration Resistance
± 1.5 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Fc
5 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc
Shock Resistance
100 G / 6 ms
acc. to IEC 60068-2-27, test Ea
Tripping Type
Thermal
Actuation Type
Reset type
Weight
ca. 10 g
Rated current | Construction variants | Order Number | Symbols, Footprints, 3D-Models | Free Sample Free Sample
|
Distributor Stock Check Distributor Stock Check
|
... | |
---|---|---|---|---|---|---|---|
Shunt terminal | Setting indication | ||||||
0.5 A | 4400.0391 |
|
... | ||||
1.5 A | 4400.0389 |
|
... | ||||
3.0 A | • | 4400.0535 |
|
... | |||
3.0 A | • | 4400.0585 |
|
... | |||
6.5 A | • | 4400.0805 |
|
... |
Packaging Unit | 100 Pcs |